Project management and electrical engineering services including specificationfor a standby generator, ATS, and upgrade of the incoming utility's service and metering equipment.
Advisor and Quality Assurance Reviewer (QAR) responsible for the quality control of the electrical design for a new reclaim
conveying system and building utilities for a wood pellet storage shed.
Technical Advisor and Quality Assurance
Reviewer (QAR) responsible for the
preparation of single line drawings and a
prefeasibility study report for the new upgrade/expansion
Lead Electrical Engineering services for 60-day plan to design, procure and manage the construction process for the coal expansion project through Engineering, Procurement and Construction Management (EPCM) project delivery approach.
Lead electrical engineering services for upgrading the plant’s electrical service from 230V to 600V. Project included
replacement of utility transformers, service conductors, service equipment, and addition of a new MCC for a new expansion.
Lead Electrical Engineering services for design and construction supervision of a new harbour plant
Project Management for the design and replacement of an existing 69KV – 12KV distribution substation with a new 69KV – 25KV station. The project included a removal plan,detailed design of the new substation, and tendering of major equipment.
Electrical Engineering services for the design, development,programming, and commissioning of automation control systems including Modicon PLCs and Wonderware SCADA systems for the
existing pump houses and lift stations.
Lead Electrical Engineering and Project Management services for multiple capital improvement and maintenance projects at the terminal over multiple years.
Lead Electrical Engineer for conducting energy audit of an existing facility at the mine site. Project included inspection of facility’s power generators and distribution systems, system evaluation and analysis, and energy audit report.
EOR services for an addition of 25,000 square feet including newsrooms and broadcasting studios, parking; renovation of 100,000 square feet of newsrooms, studios,office areas and associated spaces; and upgrade of the building’s electrical systems.
Lead Electrical Engineer for the addition of a relocated zinc borate system to Dawson Creek OSB plant. Project included power distribution, instrumentation and control systems design.
Project Management and Lead Electrical and Automation Engineering services for multiple capital improvement projects in Kitimat.
Lead Electrical Engineering services for upgrading/renovations multiple projects at University of British Columbia.